Specifications
Frequency range |
10.0kHz ~ 54.0MHz |
Dimensions |
20.1 x 12.5 x 8.0mm |
Frequency stability |
±0.3ppm max first year ±2.5ppm max in 10 years ±0.1ppm max vs VDD ±10ppb max vs load ±10% |
Short term stability |
1x10-10 max, t 0.1 to 30s 5x10-11 typ at 1s |
Storage temperature range |
-55 to +125°C |
Output waveform |
CMOS ‘0’=+0.4V max, ‘1’=VDD-0.5V min 40:60 max Rise / fall times 7ns max (no load) |
Load |
3pF min, 47pF max |
Start up time |
5ms max |
Supply voltage (VDD) |
+5.0V (±0.20V) |
Input current (mA max) |
300mA max for up to 10s @ 25°C during start up 50mA max @ +25°C 80mA max @ -20°C |
Warm up time (secs) |
20s to within ±0.1ppm @ 25°C |
Phase noise (dB typ @ 10.0MHz) |
-100dBc/Hz @ 10Hz -130dBc/Hz @ 100Hz -140dBc/Hz @ 1kHz -145dBc/Hz @ 10kHz |
Shock & vibration |
5,000g, 0.3ms ½-sine 10.0 ~ 2,000Hz, 20g |
Package Drawing
Ordering Information
To request a quotation for the SCOCXOLV please use the configurable options form to choose the options you require and then submit your configured product to our team. Our expert advisers are always happy to help with your requirements and can be contacted on +44 1460 256 100 or at sales@golledge.com.
Following product selection you will be issued with a seven character Golledge part number. Your Golledge part number is the internationally accepted Golledge manufacturing part number (MPN) that should be used for all project documentation, including bills of materials (BoMs) and purchase orders.
If you have any queries regarding any of our documentation our dedicated sales team will be happy to help.
Applications
- Digital switching
- Telecomm transmission
- SONET, SDH, DWDM, FDM/36, WIMAX
- Airborne equipment
- Battery operated systems
Soldering Profile
Handling & Storage
Human Body Model (HBM) 1A (250V to <500V)
Moisture Sensitivity Level (MSL): 1 (or not applicable)
Construction
Resistance weld
Compliance
RoHS compliant with no exemptions. See our declaration
REACH compliant. See our statement
Free of conflict minerals. See our declaration
Free of Halogens. See our declaration
Free of Ozone-depleting substances. See our declaration